Overview of the role

Planning, preparing and safely carrying out work activities in door automation.

Powered pedestrian door installer and service engineer

Reference Number: ST0373

Details of standard

Typical job titles - Automatic Door Technician/Engineer, Automatic Pedestrian Door Technician/Engineer, Automatic Door Service Technician/Engineer, Automatic Pedestrian Door Service Technician/Engineer

Occupational profile - The Powered Pedestrian Door (commonly referred to as Automatic Doors) Installer and Servicer is a specialist occupation, involved in planning, preparing and safely carrying out work activities in door automation. An installer/servicer will be able to work on a range of powered doors such as sliding, swing, folding, balanced and revolving.

The work is carried out in a variety of applications supporting business activities in a wide variety of sectors. Providing barrier free building access supports businesses in meeting the requirements of the equality act, building security, providing user comfort and contributing to meeting environmental obligations. Generally powered pedestrian doors are found in buildings, for example offices, residential property, hospitals, transport interchanges, banks, education facilities and supermarkets however, they are also common in cruise ships and large portable trailers such as medical screening trailers. Installations can take place on new building sites, during refurbishment of buildings and in end user occupied buildings.

Key activities are: the installation, routine maintenance, fault finding and repair, commissioning and de- commissioning of powered pedestrian doorsets. They have a thorough understanding of the engineering principles and safe operation of powered pedestrian doorsets. They work without immediate supervision, and liaise effectively with other trades and with end users.  The safety of themselves, work colleagues and ensuring that powered pedestrian doors used by the general public and employees are efficient and safe to use is a key responsibility.

The more widespread application of powered pedestrian doors, combined with evolving safety legislation and technology means that the requirements for skilled people in this sector are constantly growing.

The core skills and knowledge can be transferred to other applications such as the industrial door, manual door, gate and security sectors where drive controls and safety systems are used.

Requirements: Knowledge, Skills and Behaviours –

Knowledge

What is required

Underpinning principles

  • Sound understanding of Drive systems, electricity, sensors, switching technology, machinery safety and risk assessment.

Legislation, Regulations and Standards

  • Understanding of relevant UK and international standards, technical and environmental legislation including health & safety, environmental protection and working with electrical circuits.
  • Knowledge of industry Codes of Practice and other sources of up to date information and advice on technical safety and legislative aspects of their work: BS EN 16005:2012, BS7036 1996 Parts 1-5, BS7036-0 2014.

Data analysis

  • Ability to understand assembly diagrams and architectural drawings, calculations for door speeds and energy levels, force gauges, charts, door settings and tables.

System fundamentals

  • Understanding of the function and operation of door system components and how they interact in a range of different systems and applications.

Skills

What is required

Control circuit application

  • Electrical wiring and control systems setting, testing and fault finding; and their integration with motors, control boards and safety sensors applicable to powered pedestrian doors.

Mechanical operations

  • Measuring building openings and correctly positioning and fixing the door components and automatic drive unit. Connecting, adjusting and testing the installed system and relevant activation and safety sensors.
  • Appropriate selection and correct use of hand and power tools: drills, laser level, powered saws, socket set, multi meter.

Safe working practices

  • Dynamic hazards analysis and risk assessment during the working process, installation, commissioning, testing, fault diagnostics and servicing of powered pedestrian doors.
  • Working with mechanical, electrical circuits and systems.
  • Within the process of decommissioning and dismantling powered pedestrian doors - the safe disposal of equipment and waste transfer.

Data application

  • Ability to interpret and apply door systems safety data using charts, tables and formulae. Ensuring maximum door speeds and kinetic energy levels are not exceeded.

Logical problem solver

  • Employs systematic processes, and a logical approach to problem solving and technical challenges within powered pedestrian door applications.

Behaviours

What is required

Personal responsibility

  • Takes responsibility for personal presentation, work and interactions with colleagues, customers, suppliers and subcontractors.

Self- motivated

  • Willingness to learn and commitment to professional development and to applying principles of sound engineering.

Safety approach

  • Self-disciplined approach to assessing, managing, mitigating and avoiding risk in a variety of situations to themselves, colleagues, the public and the environment.

Strong work ethic

  • Positive ethical attitude and behaviours including reliability, willingness to take responsibility. Commitment to completing tasks and ability to work as part of a multi-disciplined team.

Focus on quality

  • Attention to detail, following procedures, planning and preparation.

Adaptable

  • Able to adapt to changes in conditions, technologies, situations and a wide variety of different working environments.

Communicates well

  • Uses a range of communications methods effectively, positively and in timely fashion.

Duration – Typically 24 months.

Mandatory Qualifications - Apprentices without English or maths at Level 2 or above must achieve level 1 and take the tests for level 2 prior to the undertaking the end-point.

Level – 2.

To be reviewed – After three years.


Crown copyright © 2024. You may re-use this information (not including logos) free of charge in any format or medium, under the terms of the Open Government Licence. Visit www.nationalarchives.gov.uk/doc/open-government-licence

Status: Approved for delivery
Level: 2
Reference: ST0373
Version: 1.0
Date updated: 24/09/2018
Approved for delivery: 24 September 2018
Route: Construction and the built environment
Typical duration to gateway : 24 months (this does not include EPA period)
Maximum funding: £9000
LARS Code: 353
EQA Provider: Ofqual
Employers involved in creating the standard: RTR Services Limited (chair), ASSA Abloy, Automatic Access Limited, Axis Automatic Entrance Systems, City Doors UK, GEZE UK, Gilgen Door Systems UK, Prosale Limited, Record UK

Version log

Version Change detail Earliest start date Latest start date
1.0 Approved for delivery 24/09/2018 Not set
Is this webpage useful?

Thank you for your feedback

Tell us about your experience